Difference between fire power monitoring system and electrical fire alarm system

The fire power monitoring system is a kind of 24h monitoring of fire fighting equipment. It will check whether the current, voltage and power of the fire protection product source are obtained to determine whether there is a short circuit, over voltage and under voltage, lack of equal power supply circuit failure, and transmit the fault type to the monitoring room to record and alert through the alarm system. The staff promptly repairs the power supply of the fire fighting equipment. Therefore, it can be ensured to a large extent that the fire-fighting equipment does not lose its function due to the problem of the power supply during the fire accident, so there is a linkage shutdown of the fire-fighting equipment.
Fire power monitoring system
Above we have introduced the basic information of the fire power monitoring system, then what is the difference between the fire power monitoring system and the electrical fire alarm system? Let us take you to the following.
First of all, the biggest difference between the fire power monitoring system and the electrical fire alarm system is that their purpose is inconsistent. Although the electrical fire alarm system is also a power failure alarm system, the electrical fire alarm system mainly provides an alarm for the electrical fire accident caused by the leakage and short circuit of the cable. The fire power monitoring system is mainly for the power supply of the fire fighting equipment. A detection feedback. Therefore, the objects responsible for monitoring are different.
There is a difference between the fire power monitoring system and the monitoring position of the electrical fire alarm system. The electrical fire alarm system is responsible for detecting the power installed in the power distribution cabinet, but according to our schematic diagram, the electrical fire alarm system is behind the power switch. This is because the electrical fire alarm system does not have the corresponding sensor. After all, it is only used to monitor the data in the cable. Therefore, it is necessary to measure the meter. He can't check various short-circuit, missing, over-voltage and other faults on the front end of the power supply. The fire-fighting power monitoring system can check and respond to various faults because it is equipped with sensors.

Light Fixture

Light Fixture,Aluminum Light Fixture,Die Casting Light Fixture,Aluminum Die Casting Led Housing

Ningbo Beilun Huari Metal Products Co., Ltd. , http://www.huari-metal.com