Maintenance of electromagnetic flowmeter

The flowmeter has its own principles of maintenance and some, here is the experience of summarizing over the years and sharing it with everyone:
1, routine maintenance
Only need to periodically check the instrument, check the environment around the instrument, remove the dirt, ensure that no water and other substances are inspected, check whether the wiring is good, check whether there is a new strong electromagnetic field device near the instrument or a new installed wire across the instrument.
If the measuring medium is easy to contaminate the electrode or precipitate or scale in the measuring tube wall, it should be regularly cleaned and cleaned.
2, fault finding
After the flowmeter starts to be put into operation or is put into operation for a period of time, it is found that the instrument is not working properly. First, check the external condition of the flowmeter, such as whether the power supply is good, whether the pipeline is leaking or is in a state of non-full pipe, whether there is air bubble in the pipe, whether the signal cable is Damage, converter output signal (ie rear position meter input loop) is open circuit. Remember to blindly disassemble the flowmeter.
3, sensor inspection
Test equipment: one 500MΩ insulation resistance tester, one multimeter.
Test steps summarized by the flowmeter:
(1) When the pipe is filled with medium, measure the resistance between terminals A, B and C with a multimeter. The resistance between AC and BC should be equal. If the difference is more than 1 time, there may be leakage of the electrode, condensation on the outer wall of the measuring tube or the junction box.
(2) In the case of lining drying, measure the insulation resistance between AC and BC with MΩ meter (should be greater than 200MΩ). Then use a multimeter to measure the resistance of the two electrodes in terminals A and B and the measuring tube (should be in short-circuit communication). If the insulation resistance is small, indicating that the electrode is leaking, the entire flowmeter should be returned to the factory for repair. If the insulation is reduced but there is still more than 50 MΩ and the inspection result of step (1) is normal, the outer wall of the measuring tube may be damp, and the inside of the outer casing may be dried by a hot air blower.
(3) Use a multimeter to measure the resistance between X and Y. If it exceeds 200 Ω, the excitation coil and its lead wire may be open or poorly connected. Remove the terminal block check.
(4) Check the insulation resistance between X, Y and C, which should be above 200 MΩ. If it is lowered, dry the inside of the casing with hot air. In actual operation, the decrease in coil insulation will result in increased measurement error and unstable instrument output signal.
(5) If it is determined that the sensor is faulty, please contact the manufacturer of the electromagnetic flowmeter. Generally, the site cannot be solved and needs to be repaired by the manufacturer.

Explosion-Proof Crane

Maximum Load:100.00t

Eurocrane Corporation is a leading global Crane manufacturer and service provider. Outfitted with advanced manufacturing equipment, our modern facility becomes the working home of many crane professionals with great expertise and experienced in the crane manufacturing industry. Hence we have the ability to ensure each product is completed to a high level of safety, reliability and quality. We offer a full range of spark-resistant, explosion-proof cranes that meet various customer needs. Our product conforms to the latest explosion protection standards. It has found wide use in food, chemical, and petroleum and natural gas industries as well as in any potentially explosive environment.

We strictly follow the related ATEX 100a (94/90/CE) directives and CE directives in making qualified chain hoist that can be used in Zone1, Zone 2, Zone 21, and Zone 22 areas as classified in the ATEX directives.

Explosion Proof Crane

Explosion Proof Crane,Explosion-Proof Single Girder Crane,Gantry Crane,Girder Bridge Hoist Crane

Eurocrane (China) Co., Ltd. , https://www.craneparts.pl